The short answer

KAIWEI summarizes the following common issues that occur when using dispensing machine valves along with proven, effective solutions: 1. 95% of dispensing valve dripping is caused by using a dispensing needle with too small an inner diameter,

How to Solve Dispensing Valve Leakage Issues on Dispensing Machines?
How to Solve Dispensing Valve Leakage Issues on Dispensing Machines?

KAIWEI summarizes the following common issues that occur when using dispensing machine valves along with proven, effective solutions:

1. 95% of dispensing valve dripping is caused by using a dispensing needle with too small an inner diameter. An undersized needle also affects air-bleeding when the valve starts operating; simply switching to a larger needle resolves this issue. Using a tapered angled needle ensures smooth fluid flow. Air trapped inside the fluid can cause dripping after the valve closes; it is best to purge air from the fluid beforehand, switch to an adhesive less prone to entraining air bubbles, or centrifugally degas the adhesive before use.

2. Inconsistent dispensing volume mainly occurs when the fluid pressure tank or pressure supply is unstable. The air inlet pressure regulator should be set 10 to 15 Mpa lower than the minimum plant air supply pressure. The operating pressure of the pressure tank should be above the midpoint of the regulator gauge—avoid operating in the lower-to-middle range of the pressure gauge. The valve control pressure should be at least 60 Mpa or higher to ensure stable dispensing. Next, check the dispensing time: if it is less than 15/1000 seconds, dispensing will become unstable; the longer the dispensing time, the more stable the output.  

3. If the flow rate is too slow, upgrade the tubing from 1/4" to 3/8". Keep the tubing as short as possible unless extra length is required.

4. To eliminate air bubbles in the fluid, reduce the fluid pressure and use a tapered angled needle.     

Dispensing Machine Valve Leakage

  • Dispensing Machine
  • Dispensing Machine Manufacturer
Scope of this article

Technical specifications, document scope and sealing performance require project-specific review and sample validation with KAIWEI engineering.

Equipment information Documentation scope

Next step

Discuss your part with KAIWEI

Share the drawing, material and target output for an application review.

Request an application review
← Prev: Troubleshooting: U-Axis Mixing Rod F... Back to Technology Frontier Next: Comparison Between Manual Foamed Rub... → Back to top ↑