The short answer

Causes and specific solutions when the (U-axis) mixing rod fails to rotate during fully automatic dispensing machine operation.

Troubleshooting: U-Axis Mixing Rod Fails to Rotate During Fully Automatic Dispensing Machine Operation
Troubleshooting: U-Axis Mixing Rod Fails to Rotate During Fully Automatic Dispensing Machine Operation

Causes and specific solutions when the (U-axis) mixing rod fails to rotate during fully automatic dispensing machine operation. Based on years of dispensing experience, Shanghai Kaiwei Intelligent Technology (Group) Co., Ltd. has summarized the following causes affecting the mixer/agitator

Shanghai Kaiwei Dispensing Machine

Causes of Failure to Rotate Normally:

1. The 220V power supply for the U-axis mixing motor is not turned on.

2. The wiring for the U-axis mixing motor is damaged or loose.

3. The mixing rod or bearings are seized/jammed.

4. The U-axis servo drive triggers alarm 16, 21, or 24.

Specific Solutions:

1. Turn on the 220V power switch for the U-axis mixing motor.

2. Inspect the wiring of the U-axis mixing motor and firmly plug in both the front and rear power connectors of the U-axis mixing motor.

3. Inspect whether the mixing chamber is clean and whether the bearings are damaged and require replacement.

4. Turn off the power and restart the machine.

  • Shanghai Kaiwei Dispensing Machine
Scope of this article

Technical specifications, document scope and sealing performance require project-specific review and sample validation with KAIWEI engineering.

Equipment information Documentation scope

Next step

Discuss your part with KAIWEI

Share the drawing, material and target output for an application review.

Request an application review
← Prev: Preparation and Precautions for Disp... Back to Technology Frontier Next: How to Solve Dispensing Valve Leakag... → Back to top ↑